28
Appendix 2 Default Flammable Correction Factors Triple Plus+ and Triple Plus+ IR
Appendix 2 Default
Flammable Correction Factors
This information is for the Triple Plus+ model ONLY
Gas Correction with
respect to methane
Correction with
respect to pentane
3 character name
Pentane 2.0 1.0 PEN
Methane 1.0 0.5 CH4
Butane 1.7 0.9 BUT
Propane 1.4 0.7 PRO
Hydrogen 0.9 0.5 H2
Toluene 2.7 1.4 TOL
Ethanol 1.6 0.8 ETH
Petrol
Vapour
2.5 1.3 PET
Ammonia 0.7 0.4 NH3
Methanol 1.3 0.7 MTL
LPG 1.4 0.7 LPG
Propanol 2.0 1.0 PRL
Note that these correction factors apply to VQ32 pellistor sensor modules. The
factors only apply to the Triple Plus+ and may differ if an alternate sensor mod-
ule is fitted to the instrument.